Insulation and installation of window and door frames, thermal insulation of water supply, sewage and central heating networks, sealing and installation of window sills, thermal and sound insulation of roofs and ceilings, filling and sealing of large cavities, creation of soundproofing screens; filling cavities around pipes, insulation of thermal panels, etc.
| Color | light yellow |
| Working temperature of the base, from ... to, °C | +5 ... +30 |
| Heat resistance (after curing), from ... to, °C | -50 ... +90 |
| Flammability | B3 (DIN 4102) |
| Time to disappear from sticking, min (20°C / rel. humidity 90%) | 4-8 |
| Time after which the cured foam can be cut, min | 45-55 |
| Time to complete curing, h | 24 |
| Dimensional stability after curing max., %:
- testing conditions wet seam - testing conditions dry seam |
± 1.5 ± 5 |
| Maximum joint width, cm | 4 |
| Output from the cylinder, to, l (depending on the temperature and humidity of the environment) | 65 |
| Thermal conductivity, W/(m K) | 0,036 |
| Water absorption after 24 hours in water with partial immersion, kg/m2 | ≤1 |
| Solubility in organic solvents | acetone, before curing |
| * All measurements are made under normal climatic conditions (+23°C+ 2°C, relative humidity 50 ±5%), unless otherwise stated. |
Insulation and installation of window and door frames, thermal insulation of water supply, sewage and central heating networks, sealing and installation of window sills, thermal and sound insulation of roofs and ceilings, filling and sealing of large cavities, creation of soundproofing screens; filling cavities around pipes, insulation of thermal panels, etc.
| Color | light yellow |
| Working temperature of the base, from ... to, °C | +5 ... +30 |
| Heat resistance (after curing), from ... to, °C | -50 ... +90 |
| Flammability | B3 (DIN 4102) |
| Time to disappear from sticking, min (20°C / rel. humidity 90%) | 4-8 |
| Time after which the cured foam can be cut, min | 45-55 |
| Time to complete curing, h | 24 |
| Dimensional stability after curing max., %:
- testing conditions wet seam - testing conditions dry seam |
± 1.5 ± 5 |
| Maximum joint width, cm | 4 |
| Output from the cylinder, to, l (depending on the temperature and humidity of the environment) | 65 |
| Thermal conductivity, W/(m K) | 0,036 |
| Water absorption after 24 hours in water with partial immersion, kg/m2 | ≤1 |
| Solubility in organic solvents | acetone, before curing |
| * All measurements are made under normal climatic conditions (+23°C+ 2°C, relative humidity 50 ±5%), unless otherwise stated. |