Cement screed for arranging and leveling the floor before laying tiles and other coatings inside and outside buildings.
Thanks to the improved special formula, the product provides:
• the ability to easily distribute and level the screed at an angle (perform a screed);
• a wide range of layer thicknesses (10-100** mm.) ensures use in mortise structures;
• compressive strength (≥ 25 MPa) allows the product to be used not only in residential areas, but also in garages, warehouses, etc. (with weak mechanical influences);
• installation of “warm floor” systems.
| Mixing water proportions | 0,14 - 0,16 L / 1 kg 3,5 - 4,0 L / 25 kg |
| Recommended thickness of the levelling layer, min-max, mm | 10 - 40 |
| *coverage area from 1 bag of 25 kg of dry mix (layer thickness 10 mm), m² | 1.3 |
| **recommended layer thickness with the addition of fractionated crushed stone 2-5 mm, max. | 100 |
| The service life of the mortar mix for laying, min | 20 |
| The term of readiness of the levelling layer after laying, days - technological passage - laying of ceramic tiles - laying of other coatings |
1 3 7 |
| Compressive strength, N/mm², not less | ≥ 25 |
| Bending tensile strength, N/mm², not less than | ≥ 4 |
| The temperature of the base and ambient temperature during application, °С | +5 ... +30 |
Cement screed for arranging and leveling the floor before laying tiles and other coatings inside and outside buildings.
Thanks to the improved special formula, the product provides:
• the ability to easily distribute and level the screed at an angle (perform a screed);
• a wide range of layer thicknesses (10-100** mm.) ensures use in mortise structures;
• compressive strength (≥ 25 MPa) allows the product to be used not only in residential areas, but also in garages, warehouses, etc. (with weak mechanical influences);
• installation of “warm floor” systems.
| Mixing water proportions | 0,14 - 0,16 L / 1 kg 3,5 - 4,0 L / 25 kg |
| Recommended thickness of the levelling layer, min-max, mm | 10 - 40 |
| *coverage area from 1 bag of 25 kg of dry mix (layer thickness 10 mm), m² | 1.3 |
| **recommended layer thickness with the addition of fractionated crushed stone 2-5 mm, max. | 100 |
| The service life of the mortar mix for laying, min | 20 |
| The term of readiness of the levelling layer after laying, days - technological passage - laying of ceramic tiles - laying of other coatings |
1 3 7 |
| Compressive strength, N/mm², not less | ≥ 25 |
| Bending tensile strength, N/mm², not less than | ≥ 4 |
| The temperature of the base and ambient temperature during application, °С | +5 ... +30 |